Helideck
-------------------------------------------------------------
The heliport is designed to service the Sikorsky S-61N Helicopter and is located forward of the bow of the unit.
Operation Conditions
-------------------------------------------------------------
Max.Temperature 300 ° F
Min. Temperature -20 ° F
Max. Pressure (Plant Inlet) 1310 psig
Min. Pressure (Plant Inlet) full vacuum
Max. Crude Oil Water Cut At The Plantinlet 25%
Min. Crude Oil Water Cut (Plant Inlet) 0%
Process Liquids Specific Gravity Range 0.7 - 1.5
Crude Oil API Gravity Range 10 ° - 49 ° API
Process Fluids pH Range 5 - 9
Typically, pH is neutral (7)
Design Capacity
-------------------------------------------------------------
Diesel Engine Generators One operating unit/One standby unit
(700 kW each) (Output: 440 V / 3 Phase / 60 Hz)
Hydraulic Power Units One big (1600 kW) for re-injection pumps
/ One small (800 kW) for export pumps
Design Parameters
-------------------------------------------------------------
Max. Liquid handling Capacity (Plant Inle 20,000 bbls/day
Max. Water Cut 2%
Normal Max. Gas Flaring Capacity (Continuous) 60 MMscfd
Oil Export Rate 1050 GPM @500 psig
Water Re-injection Rate 700 GPM @3000 psig
WTSV : Well Test Service Vessel
-